Setting APO Time

Used to set a time until APO (Auto Power OFF) occurs.

SYNTAX

int SYS_SetApoTime (int nValue);

INPUT

nValue =

APO time

0

Does not cause APO.

1 to 15

Causes APO in the specified-number of minutes plus
30 seconds.

The actual APO time has an error of +/- 25 seconds.

OUTPUT

= 0 Normal

= -1 Parameter error

Note :

Auto Power OFF will work if the power control function is active. For more information about the

power control function refer to "Setting/Acquisition of Status of Power Control Function".