Section 4: operation, Receptacles, Generator adapter cord set – Troy-Bilt 01919-1 User Manual

Page 10: Caution, Nema li

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Section 4: Operation

RECEPTACLES

Figure 6 — 120 Volt, 20 Amp Duplex Receptacle

^ CAUTION

Receptacles may be marked with rating value greater

than generator output capacity.

NEVER attempt to power a device requiring more amperage

than generator or receptacle can supply.

DO NOT overload the generator. See “Don’t Overload
Generator”.

120/240 Volt AC, 30 Amp, Locking

Receptacle_____________ ^_______

Use a NEMA LI4-30 plug with this receptacle. Connect a

4-wire cord set rated for 250 Volt AC loads at 30 Amps (or

greater) (Figure 5). You can use the same 4-wire cord if you

plan to run a 120 Volt load.

Figure 5 — 120/240 Volt AC, 30 Amp Receptacle

4-Wire Cord Set

NEMA LI

4-30

This receptacle powers 120/240 Volt AC, 60 Hz, single

phase loads requiring up to 5,550 watts of power

(5.55 kW) at 23.1 Amps for 120 Volts or 240 Volts.The

outlet is protected by a push-to-reset circuit breaker.

120 Volt AC, 20 Amp, Duplex

Receptacles__________________

Each duplex receptacle (Figure 6) is protected against

overload by a push-to-reset circuit breaker.

Use each receptacle to operate 120 Volt AC, single—phase,

60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)

at 20 Amps of current. Use cord sets that are rated for

125 Volt AC loads at 20 Amps (or greater).

GENERATOR ADAPTER

CORD SET

The generator is equipped with a 25’ generator adapter cord

set designed for a 240Volt, 30 Amp grounded neutral Circuit

(Figure 7).The generator adapter cord set provides a

convenient supply of emergency power into your dwelling so

that your generator can be operated safely outside.

Figure 7 — Generator Adapter Cord Set

The maximum load on each outlet is 20 Amps.The

maximum total load on both yellow wire outlets or black

wire outlets is 30 Amps.

NOTE:

Follow all safety precautions when connecting any

extension cord or device to the generator.

Advertising