SPECIFICATIONS

Starting Watts .... ................................................................ 8,550 watts

Wattage ................................................................................. 5,550 watts

AC Load Current:

At 120 Volts....................................................................................46.2 Amps

At 240 Volts....................................................................................23.1 Amps

Phase ......................................................................................... I-phase

Rated Frequency.................................................................................... 60 Hertz

Fuel Tank Capacity.......................................................5 U.S. gallons

Shipping Weight....................................................................... 169 lbs.

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that

all periodic maintenance tasks are completed on a timely

basis; that all discrepancies are corrected; and that the unit

is kept clean and properly stored.

NEVER operate a

damaged or defective generator.

Should you have questions about replacing components on

yourTroy-Bilt® generator, please call

1-888-61 1-6708

for

assistance.

Engine Maintenance________________

See engine owner’s manual for instructions.

^ CAUTION

Avoid prolonged or repeated skin contact with used

motor oil.

Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T

POLLUTE. CONSERVE RESOURCES. RETURN

USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean

and dry. Operate and store the unit in a clean dry

environment where it will not be exposed to excessive

dust, dirt, moisture or any corrosive vapors. Cooling air

slots in the generator must not become clogged with snow,

leaves or any other foreign material.

NOTE:

DO NOT gse a garden hose to clean generator.

Water can enter engine fuel system and cause problems. In

addition, if water enters generator through cooling air slots,

some of the water vvill be retained in voids and cracks of

the rotor and stator winding insulation.Water and dirt

buildup on the generator internal windings will eventually

"decrease the insulation resistance of these windings.

Generator Cleaning '________________

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and

shorten its life.

• DO NOT expose generator to excessive moisture, dust, dirt,

or corrosive vapors.

> DO NOT insert any objects through cooling slots.

• Use a soft bristle brush to loosen caked on dirt or oil.

• Use a vacuum cleaner to pick up loose dirt and debris.

• ,Use low pressure air (not to exceed 25 psi) to blow away

dirt. Inspect cooling air slots and opening on generator.

These openings must be kept clean and unobstructed.

Data Tag__________________________

Data tag information is very important if you need help from

our Customer Service Department or an authorized service

dealer.

• The data tag (Figure 9) is located either on the heat shield

or engine support on the muffler side of the generator.

For future reference, please copy the model, revision, and

serial number of the generator in the space below.

Figure 9 — Data Tag