Table 2-1 controller specifications – Compaq RAID ARRAY 3000 EK-SMCPO-UG. C01 User Manual

Page 39

Advertising
background image

RAID Array Controller 2-5

Compaq Confidential – Need to Know Required

Writer: Bob Young Project: RAID Array 3000 Pedestal Storage Subsystem Hardware User’s Guide Comments:

Part Number: EK-SMCPO-UG. C01 File Name: c-ch2 RAID Array Controller.doc Last Saved On: 12/4/00 1:51 PM

Stripesets (RAID 0) combine disk drives in serial to increase transfer or
requests rates

Mirrorsets (RAID 1) combine disk drives in parallel to provide a highly
reliable storage unit

RAID 4 provides striping with a fixed parity drive

RAIDsets (RAID 5) combine disk drives in serial— just like stripesets
— but also store parity data to ensure high reliability

Stripe mirrorsets (RAID 0 + 1) combine mirrorsets in serial to provide
the highest throughput and availability of any storage unit

Table 2–1 lists the features of the RAID 3000 controller.

Table 2-1

Controller Specifications

Item

Specifications

Environmental monitoring

High availability fault bus support via EMU

Processor

40 MHz, 32 bit LR33310 RISC CPU

System bus interface

Two, Wide, differential UltraSCSI channels

Configuration

Two RS232 serial ports

RAID levels supported

0, 1, 0+1, 4, 5

Drive channels supported

Two, Wide, UltraSCSI single-ended channels

Number of logical drives (LUN’s)

Up to 30 RAID sets, and up to 16 redundancy
groups (LUNs) per RAID set

SCSI channels

Two, UltraSCSI, 16-bit, single-ended

Metadata

20 blocks/disk (10240 bytes)

Largest allowable disk/RAID set/LUN

Two, 32 blocks (approximately 2.2 petabytes)

Non-RAID device support

Disk drives (JBOD)

Drives supported

StorageWorks 2, 4, 18, and 36 GB SCSI and
UltraSCSI drives.

Drive reconstruct

Automatic with hot or warm spares

Disk hot plug

Yes

Disk hot spare (spinning)

Yes, global hot spare

continued

Advertising