Voltage Monitoring

System Voltage

The controller monitors the incoming system voltage levels and ensures that
they are satisfactory for controller operation. The acceptable voltage levels are
listed in Table 2–7.

Table 2-7

Acceptable System Voltage Levels

State

Range

Action

Normal

4.80 to 5.25 V

Normal operation

Low warning

4.75 to 4.80 V

Alarm

High warning

5.25 to 5.30 V

Alarm

Low severe

Less than 4.75 V

Off line

High severe

Greater than 5.30 V

Off line

Termination Voltage

The controller monitors the incoming termination voltage levels and ensures
that they are satisfactory for controller operation. The acceptable voltage
levels are shown in Table 2–8.

Table 2-8

Acceptable Termination Voltage Levels

State

Range

Action

Normal

4.20 to 5.40 V

Normal operation

Low warning

4.00 to 4.20 V

Alarm

High warning

5.40 to 5.55 V

Alarm

Low severe

Less than 4.00 V

Off line

High severe

Greater than 5.55 V

Off line

Advertising