12 V Supply Voltage

The controller monitors the incoming 12-volt levels and ensures that they are
satisfactory for operation. The acceptable voltage levels are listed in
Table 2–9.

Table 2-9

Acceptable 12 Volt Levels

State

Range

Action

Normal

10.80 to 13.80 V

Normal operation

Low warning

10.20 to 10.80 V

Alarm

High warning

13.80 to 14.40 V

Alarm

Low severe

Less than 10.20 V

Off line

High severe

Greater than 14.40 V

Off line

Temperature Monitoring

External Temperature

The controller monitors the external operating temperature and ensures that
they are satisfactory for controller operation. The acceptable temperature
levels are listed in Table 2-10.

Table 2-10

Acceptable External Temperature Levels

State

Temperature

Action

Normal

< 106ºF (41ºC)

Normal operation

High warning

< 106ºF to 126ºF

(41ºC to 52ºC)

Alarm

High severe

> 133ºF (52ºC)

Off line