Compaq RAID ARRAY 3000 EK-SMCPO-UG. C01 User Manual

Page 40

Advertising
background image

2-6 RAID Array 3000 Pedestal Storage Subsystem Hardware User’s Guide

Compaq Confidential – Need to Know Required

Writer: Bob Young Project: RAID Array 3000 Pedestal Storage Subsystem Hardware User’s Guide Comments:

Part Number: EK-SMCPO-UG. C01 File Name: c-ch2 RAID Array Controller.doc Last Saved On: 12/4/00 1:51 PM

Table 2-1
Controller Specifications

continued

Item

Specifications

Disk warm spare (not spinning)

Yes, global warm spare

Redundant power supplies

Yes

Redundant controllers

Yes

Controller failover

Yes, automatic

Controller hot spare

Yes (Active/Passive mode)

Controller hot plug

Yes

Cluster support

Yes, single (SCSI) bus cluster

Maximum number of units presented to host

64

Maximum host port transfer speed

20 MHz

Command queuing

Yes, 64 commands (host and disk SCSI
channels)

Heterogeneous multi-host support

Yes

Mixed drive types

Yes

Configurable reconstruct time

Yes

Stripe size (chunk size)

Variable

Write through cache

Yes, user selectable (optional)

Write back cache

Yes, user selectable (default)

Write on top

Yes

Write gathering

Yes

Battery backup for cache

Yes, Pedestal Uninterruptable Power Supply
(UPS)

Boot capability

Bootable from RAID set (system-dependent)

Number of controllers /system

Two

Cache support

Up to 64 MB (using two 32 MB industry
standard, 72-pin, 36-bit, 60 ns SIMMS)

FCC rating

Class B

continued

Advertising