Table 2-1
Controller Specifications
continued
Item
Specifications
Disk warm spare (not spinning)
Yes, global warm spare
Redundant power supplies
Yes
Redundant controllers
Yes
Controller failover
Yes, automatic
Controller hot spare
Yes (Active/Passive mode)
Controller hot plug
Yes
Cluster support
Yes, single (SCSI) bus cluster
Maximum number of units presented to host
64
Maximum host port transfer speed
20 MHz
Command queuing
Yes, 64 commands (host and disk SCSI
channels)
Heterogeneous multi-host support
Yes
Mixed drive types
Yes
Configurable reconstruct time
Yes
Stripe size (chunk size)
Variable
Write through cache
Yes, user selectable (optional)
Write back cache
Yes, user selectable (default)
Write on top
Yes
Write gathering
Yes
Battery backup for cache
Yes, Pedestal Uninterruptable Power Supply
(UPS)
Boot capability
Bootable from RAID set (system-dependent)
Number of controllers /system
Two
Cache support
Up to 64 MB (using two 32 MB industry
standard, 72-pin, 36-bit, 60 ns SIMMS)
FCC rating
Class B
continued