Installation Procedure

Step 5.

Set Array

Input Voltage

Switch

Before you connect the array’s power cord to an AC outlet, you must set the
array power supply’s input voltage selection switch to the proper position: the
“115” setting for 100-120 VAC, or the “230” setting for 200-240 VAC.

The power supply’s input voltage selection switch is located between the two
power cord connectors on the rear panel of the array.

Caution

If the input voltage selection switch is not in the correct position,
the array power supply will be damaged when power is applied.

Step 6.

Attach Power

Cord

First, verify that the array power ON/OFF switch on the rear panel of the
enclosure is in the OFF position. Then plug the power cord into the appropriate
connector on the rear panel of the array. Plug the other end of the power cable
into the power source.

Caution

The standard power cord provided with the array is for use in the
United States and Canada. If necessary, replace the power cord
with one that meets local safety and electrical standards.

Step 7.

Power Up the

Array

Move the power switch on the rear panel of the array enclosure to the ON
position.

Step 8.

Check Array

Status

Observe the display/operation panel for the following start-up displays and
status indications.

Drive Status

At array reset or power-up, the display/operation panel will cycle through a
series of displays that show the status of each drive in the array.

Drives in the array are numbered from right to left, with drive number 1
representing the parity drive and drives 2-9 representing the eight data drives.

9 8 7 6 - 5 4 3 2 - 1

(Drive 1 = Parity Drive)