21020690 B

6500 Disk Array User’s Guide

Chapter 3 Display/Operation Panel

Page 3 - 18

REBUILD

REBUILD

From

)81&7,21 6(/(&7, use the left/right arrow keys to select the following

5(%8,/' functions (see “Menu Structure (3 of 5—Array Info & Rebuild)” on
page 3-8)
. Use the display/operation panel rebuild options listed below as
described in Chapter 4 of this guide.

Caution

If a disk in the array fails, replace the drive and perform a rebuild
as soon as possible. A rebuild can be performed without taking the
array off-line. See Chapter 4 for drive replacement and rebuild
instructions.

REBUILD

DATA

Your selection for the

5(%8,/' '$7$ parameter determines whether or not

the data from the failed drive will be reconstructed on the new replacement disk
drive.

21 means the data will be rebuilt; 2)) means the data will not be rebuilt.

Caution

'$7$ 21 should always be selected for a data rebuild. Rebuilding
with this selection

2)) may result in data corruption and/or inter-

drive parity errors.

REBUILD%

This menu selection allows you to select the percentage of processing time the
array will dedicate to the rebuilding process:

   , or  . The lower

the percentage, the longer the rebuild will take. The default setting is

 .

START

This selection must be set to

<(6 before you press SELECT to rebuild a drive.