Rebuild, Rebuild data, Start – Ciprico 6500 User Manual
Page 48
21020690 B
6500 Disk Array User’s Guide
Chapter 3 Display/Operation Panel
Page 3 - 18
REBUILD
REBUILD
From
)81&7,21 6(/(&7, use the left/right arrow keys to select the following
5(%8,/' functions (see “Menu Structure (3 of 5—Array Info & Rebuild)” on
page 3-8). Use the display/operation panel rebuild options listed below as
described in Chapter 4 of this guide.
Caution
If a disk in the array fails, replace the drive and perform a rebuild
as soon as possible. A rebuild can be performed without taking the
array off-line. See Chapter 4 for drive replacement and rebuild
instructions.
REBUILD
DATA
Your selection for the
5(%8,/' '$7$ parameter determines whether or not
the data from the failed drive will be reconstructed on the new replacement disk
drive.
21 means the data will be rebuilt; 2)) means the data will not be rebuilt.
Caution
'$7$ 21 should always be selected for a data rebuild. Rebuilding
with this selection
2)) may result in data corruption and/or inter-
drive parity errors.
REBUILD%
This menu selection allows you to select the percentage of processing time the
array will dedicate to the rebuilding process:
, or . The lower
the percentage, the longer the rebuild will take. The default setting is
.
START
This selection must be set to
<(6 before you press SELECT to rebuild a drive.