Disabling a failed disk drive, Press the down arrow on the display/operation p, Press the down arrow – Ciprico 6500 User Manual

Page 77: Press the right or left arrows until the disabl, Press the right or left arrows until the desire, Press select. the selected drive is disabled

Advertising
background image

6500 Disk Array User’s Guide

21020690 B

Chapter 4 Maintenance, Troubleshooting & Hardware Replacement

Disabling a Failed Disk Drive

Page 4 - 23

Disabling a
Failed Disk
Drive

This procedure allows you to disable one drive in the array. The array stops
operations on the selected drive and allows it to be physically removed.

Note

The array prevents any drive from being disabled if another drive
in the array is currently failed or disabled.

The procedure in the following example disables Drive 5.

1.

Press the down arrow on the display/operation panel, then press the
right or left arrows until the

)81&7,21 6(/(&7'5,9(6 menu is

displayed.

2.

Press the down arrow.

3.

Press the right or left arrows until the

',6$%/( '5,9(  menu is

displayed.

4.

Press the down arrow.

5.

Press the right or left arrows until the desired drive number (e.g., 5) is
displayed.

6.

Press SELECT. The selected drive is disabled.

Advertising