Array options, Table 2: array options, On/off line – Ciprico 6500 User Manual

Page 41: Scsi id

Advertising
background image

6500 Disk Array User’s Guide

21020690 B

Chapter 3 Display/Operation Panel

ARRAY OPTIONS

Page 3 - 11

ARRAY
OPTIONS

From

)81&7,21 6(/(&7, use the left/right arrow keys to select $55$<

237,216 (see “Menu Structure (1 of 5—Array Options)” on page 3-6 and
“Menu Structure (2 of 5—Array Options)” on page 3-7). Array options include:

ON/OFF LINE

When ON LINE, the array is ready to receive commands from the system it is
connected to.Take the array OFF LINE if you want to prevent user access while
performing a rebuild or other maintenance.

SCSI ID

Each device on the SCSI bus must have a unique ID. This option allows you
to set the array's SCSI ID from 0 to 15. This is typically set to 0 unless multiple
arrays are daisy-chained together or the ID of the host SCSI port is zero.

OPTION

DEFAULT SETTING

ON/OFF LINE

ON LINE (or assigned array

name)

SCSI ID

0

PASSWORD

(none)

UNIT ATTENTION

ON

WRITE PROTECT

OFF

ALARM

ON

SET DEFAULTS

NO

RPT AS RECOVER

OFF

TEMP WARNING

45 degrees C

TEMP CRITICAL

ON

AUTO MEGOMETER

OFF

ARRAY NAME

(blank)

Table 2: Array Options