35

© 2 0 0 2 d i r e c t e d e l e c t r o n i c s , i n c .

Example

If the alarm triggers three times within a 60-minute period and

each time the same sensor or switch triggers the alarm, NPC

will interpret those triggers as false alarms. After the third trigger,

NPC

ignores, or bypasses, that sensor or switch (along with any

other sensors or switches sharing the same zone) for 60 minutes.

If the bypassed sensor tries to trigger the security system while it

is being bypassed, the 60-minute bypass period will start over.

This ensures that a sensor that is continually being triggered will

remain bypassed.

The vehicle doors are protected by NPC

differently. If your

security system is triggered by an open door for three full cycles,

the system will bypass the doors until the trigger ceases.

note: Arming and disarming the system does not reset
this function! The only ways to reset a bypassed zone are
for it to not trigger for 60 minutes, or to turn on the igni-
tion. If testing your system, it is important to remember
that the NPC

programming can cause zones to be

bypassed and appear to stop working.