2.10. Power Consumption

TBD

2.11. Operating Temperatures

¾

Standard Operating Temperature:

0°C to 60°C

(wide voltage input)

¾

Extreme Rugged Operating Temperature (optional)*: -40°C to 85°C (standard voltage input)

*Intel® Atom™ E3800 Series processors only

2.12. Environmental

¾

Humidity:

5-90% RH operating, non-condensing

5-95% RH storage (and operating with conformal coating).

¾

Shock and Vibration: IEC 60068-2-64 and IEC-60068-2-27

MIL-STD-202F, Method 213B, Table 213-I, Condition A and Method 214A, Table 214-I, Condition D

¾

Halt:

Thermal Stress, Vibration Stress, Thermal Shock and Combined Test

2.13. Specification Compliance

¾

PICMG COM.0: Rev 2.1 Type 10, mini size 84 x 55

2.14. Operating Systems

¾

Standard Support:

Windows 7/8 32/64-bit, Linux 32/64-bit

¾

Extended Support (BSP):

WES7/8, WEC7, Linux, VxWorks