System management > runtime statistics, System management > flags, System management > power up – ADLINK nanoX-BT User Manual

Page 41

Advertising
background image

nanoX-BT

Page 41

Feature

Options

Description

V3.30

Read only

Display actual V3.30 voltage

VIN

Read only

Display actual VIN voltage

AIN7

Read only

Display actual AIN7 voltage

7.2.6.4. System Management > Runtime Statistics

Feature

Options

Description

Runtime Statistics

Info only

Total Runtime

Read only

The returned value specifies the total time in minutes the system
is running in S0 state.

Current

Runtime

Read

only

The returned value specifies the time in seconds the system is
running in S0 state.
This counter is cleared when the system is removed from the
external power supply.

Power

Cycles

Read

only

The returned value specifies the number of times the external
power supply has been shut down

Boot Cycles

Read only

The Bootcounter is increased after a HW- or SW-Reset or after a
successful power-up.

Boot Reason

Read only

The boot reason is the event which causes the reboot of the
system.

7.2.6.5. System Management > Flags

Feature

Options

Description

Flags Info

only

BMC

Flags

Read

only

BIOS Select

Read only

Display the selection of current BIOS ROM

ATX/AT-Mode

Read

only

Display

ATX/AT-Mode

Exception

Code

Read

only

System

exception

reason

7.2.6.6. System Management > Power Up

Feature

Options

Description

Power Up

Info only

Power Up watchdog

Attention: F12 disables the Power Up
Watchdog.

Enabled
Disabled

The Power-Up Watchdog resets the system after a certain
amount of time after power-up.

ECO

Mode

Disabled
Enable

Reduces the power consumption of the system

Power-up

Mode

Attention: The Power-Up Mode only has effect,
if the module is in ATX-Mode.

Turn on
Remain off
Last State

Turn On: The machine starts automatically when the power
supply is turned on.
Remain Off: To start the machine the power button has to be
pressed.
Last State: When powered on during a power failure the system
will automatically power on when power is restored.