Programmable thermostat control – setup options, Options, Rogrammable – Bonaire / Celair (Tekelek) User Manual

Page 17: Hermostat, Ontrol, Etup, Ptions

Advertising
background image

LP SERIES OWNER’S MANUAL

Controls Setup & Commissioning

TEK600 SERIES CONTROL

Page 17

P

ROGRAMMABLE

T

HERMOSTAT

C

ONTROL

– S

ETUP

O

PTIONS

This controller has a number of options for the installer to set before commissioning the
unit.

Options

OPERATION

FUNCTION

DUMP
DELAY

This mode controls the dump valve. (If fitted).

The dump delay is used to set the dump valve to dump 40 seconds
after the pump is turned off or can be set to dump one hour after the
pump has turned off.
After 40 seconds or 1 hour the base is drained and left dry until the
next cycle.

PRE-COOL

The pre-cool feature is used to let the pump wet the pads for 2 minutes
before the controller turns the fan on.
This feature applies to the COOL and AUTO modes.

The pre-cool can be selected to be either on or off.

DUMP
INTERVAL

The dump interval is used to cycle the dump valve (if fitted) in 1, 2, 4,
8, 12, and 24 hour cycles. If the unit is on for long periods of time or
the water has a high mineral content a dumping interval can be set to
help maintain the unit.

When the dumping time interval has timed out, (e.g.: after 4 hours of
pump operation) the unit will shut down for 2 minutes while the dump
valve drains the water from the base.
After 2 minutes the dump valve is closed, the base fills with water and
the unit starts in the same mode that it was in before the dumping
cycle commenced.

PRE-FILL

The pre-fill mode allows the base to be filled with water (if a dump
valve has been fitted) for 1 minute before starting the pump and can be
set to the on or off mode.