Setting the Thermostat Control Minimum / Maximum speed settings.
1. Start with the wall switch in the off mode.

2. Press and hold the auto and timer buttons for ten seconds then release, after

releasing these two buttons press and release the timer button once.

3. The auto light will flash continuously and the four-hour light will flash once every two

seconds, this indicates that the unit is ready for low speed adjustment. If this does
not occur repeat steps 1 and 2.

4. Rotate the adjustable dial fully anti-clockwise and press the fan button once, the fan

light will flash three times to confirm the new setting has been entered.

5. To increase the minimum speed setting rotate the dial clockwise to a desired set

point and press the fan button to enter the new setting. (NOTE: The fan speed will
not change until the fan button has been pressed).

6. If the minimum speed needs to be increased further rotate the adjustable dial and

press the fan button to enter the new setting.

Once the minimum speed has been set press the auto button to adjust the high
speed setting (go to step 7) or press the timer button once to escape the minimum
and maximum speed setting mode and return to normal wall switch operation.

7. Once the minimum speed has been set press the auto button once and the auto light

will flash continuously and the four hour light will flash twice every two seconds,
indicating that the unit is ready for maximum speed adjustment.

8. Rotate the adjustable dial fully clock-wise and press the fan button once to enter the

new setting.

9. If the maximum speed needs to be decreased rotate the dial anti-clockwise then

press the fan button to enter the new setting.

10. If the fan speed needs to be decreased further repeat step 9.

11. Once minimum and maximum speeds have been adjusted press the timer button

once to escape the minimum and maximum speed setting mode and return to normal
wall switch operation.