Operating the controls, Programmable thermostat control, Manual operation – Bonaire / Celair (Tekelek) User Manual

Page 8: Fan only, Fan & pump, Turning off unit, Ventilation, Automatic operation, Rogrammable, Hermostat

Advertising
background image

OWNER’S MANUAL

Controls Operation

TEK600 SERIES CONTROL

Page 8

Operating the Controls

Your ducted evaporative air conditioner has been supplied with either the 4-button
Programmable Thermostat control, or the 2 button manual control

P

ROGRAMMABLE

T

HERMOSTAT

C

ONTROL

The Programmable Thermostat controller has two modes, MANUAL or AUTOMATIC.
In addition it has a TIMER, which will operate in either mode.

Manual Operation
Fan Only

Pressing the FAN button once will turn on the
green fanlight and will start the fan only. The
variable speed dial will vary the speed of the
fan.

Fan & Pump

Pressing the COOL button once will turn on the
green cool light and will start the fan and pump.
The variable speed dial will vary the speed of
the fan.

*NOTE: When the COOL button is pressed there may be a two or three minute delay
in start up if PRE-FILL, or PRE-COOL has been selected in the set up of the
controller. This is indicated by a flashing green light next to the COOL button or
AUTO button. For more information on these features contact your nearest Climate
Technologies dealer or from place of purchase.

Turning off Unit

To switch the unit off, press the button that has the green light. This light will then go
out to indicate the unit is off.

Ventilation
On days of high humidity, your unit may operate more efficiently in ventilation mode.

To start the FAN ONLY press the fan button.

Use the dial to control the comfort level required (speed of the fan).

Automatic Operation

To select AUTOMATIC mode press the AUTO button. The green light will be on to

indicate that the unit is in the auto mode.

To select the desired comfort level use the dial . The dial does not control the

speed of the fan this is done automatically by the controller.

Note: The comfort level is individual to each situation and location. Some trial

and error may be required to set the dial to your desired comfort level; a
good starting point is to have the dial set at the Nine o'clock position. Once
the unit has been set, the fan speed and pump are controlled automatically.
The unit can be left and will cycle on and off to keep the area being cooled
to the set comfort level.

Around the edge of the dial there is a marking, for more cooling turn the dial

clockwise to where the marking increases in size. If the room temperature is too
cold turn the dial anti-clockwise for less cooling (a warmer comfort setting).