OWNER’S MANUAL

Ducted Evaporative Air Conditioner

TEK600 SERIES CONTROL

Page 6

I

NTRODUCTION

The Ducted Evaporative Air Conditioner is engineered to meet the rigors of our harsh
Australian environment. Operated and maintained in accordance with this manual, it
will provide you with years of quiet, cool and environmentally friendly operation.
Please take the time to read this manual.

The principal of your unit is to introduce fresh air, which is washed through the filter
pads to provided cool fresh air. The air is exhausted taking with it any heat loadings
on the home.

Exhaust
It is essential for successful operation of evaporative air-conditioning that there be
sufficient exhaust openings in the area to be ventilated. Open doors and windows will
usually provide this.

The minimum exhaust opening should be as per the table guide set out below. It is
recommended that ceiling vents or exhaust fans be used where there is any doubt
about there being sufficient exhaust area available. Ceiling exhaust fans or ceiling
vents should have a capacity equivalent to that of the air conditioner.

MODEL

MINIMUM

EXHAUST AREA

Small Cabinet

0.80 m²

Medium Cabinet

1.43 m²

Large Cabinet

1.75 m²