As needed, Jt25 operator’s manual – Ditch Witch JT25 User Manual

Page 187

Advertising
background image

Service - 186

JT25 Operator’s

Manual

As Needed

CMW

Change Fluid Pump Oil

Change fluid pump oil every 2000 hours.

To change:

1.

Drain at plug (3). Ensure that magnetic drain
plug is cleaned of debris before reinstalling.

2.

Add NDO at fill plug (2). Maintain fluid level at
fill plug (2). Inspect oil level at sight glass (1).

As Needed

Location

Task

Notes

DRILLING
UNIT

Change pipe auto lubricator TJC pail

TJC

Change hydraulic filter

Any time system is opened

Check pipeloader inserts

Check pipe guide inserts

Check fluid pump ball valve

Check track support slide pads

Change engine drive belt

Change air filter

Check wrench jaw inserts

Check SaverLok system

2

1

3

j37om024h.eps

j37om024h.eps

Advertising