As needed, Jt25 operator’s manual – Ditch Witch JT25 User Manual
Page 187
Advertising
Service - 186
JT25 Operator’s
Manual
As Needed
CMW
Change Fluid Pump Oil
Change fluid pump oil every 2000 hours.
To change:
1.
Drain at plug (3). Ensure that magnetic drain
plug is cleaned of debris before reinstalling.
2.
Add NDO at fill plug (2). Maintain fluid level at
fill plug (2). Inspect oil level at sight glass (1).
As Needed
Location
Task
Notes
DRILLING
UNIT
Change pipe auto lubricator TJC pail
TJC
Change hydraulic filter
Any time system is opened
Check pipeloader inserts
Check pipe guide inserts
Check fluid pump ball valve
Check track support slide pads
Change engine drive belt
Change air filter
Check wrench jaw inserts
Check SaverLok system
2
1
3
j37om024h.eps
j37om024h.eps
Advertising