JT25 Operator’s Manual

Controls - 51

ESID

ESID

1. Alphanumeric display

5. Current problem indicator

2. Strike indicator

6. OK indicator

3. Alarm interrupt button

7. Electrical power supply indicator

4. Voltage problem indicator

8. Self test button

Item

Description

Notes

1.

Alphanumeric display

Display amount of current
and voltage being detected
as a percentage of strike
condition.

The line with the “V” shows
voltage reading and the line
with the “A” shows current
reading.

2.

Strike indicator

Red lights come on as values
in display increase.

Light in triangle represents
strike warning condition and
will trigger alarm(s) and
strobe(s).

Remember that system can
go from one or two lights to
an electric strike immediately.

NOTICE: The ESID does not indicate
proximity to electric lines. System will
activate only when voltage and/or
amperage detected at the drilling unit
are above threshold minimum limits.

j07om042h.eps