Configure LCD sequence

1. Go to the configure column/ “LCD Display Sequence”. Select the items to be viewed on the HDR LCD screen.

Leave any items un-checked to hide them from the LCD. In the example below, if “Low Press 1” alarm was active,
the low pressure alarm would not be visible on the LCD (because it’s unchecked) but will show in the software.

The HDR has 3 types of data logs:

1. Profiler: (Core log) is programmable from 1 min up till 60 min interval. Channels are selectable (Ave/Min/Max)

Pressure 1, 2 & 3/ Temp 1 & 2/ Case Temperature & Battery voltage). This log is capable of storing large amounts
of data. This log is circular- first data in last data out. To save this file go to “Data”/ Select Downloads/ Check off
“Profiler”/ Click “OK”).

a. To configure the Profiler, go to Configure Column/ “Profiler”
b. Select each field to be recorded in the Profiler
c. Select the desired “interval in minutes” (1 min/ 5 min/ 10 min/ 15 min/ 30 min/ 60 minutes). Note: The

more often the interval, the less memory available in the HDR storage (as seen in the “Total size in days”).

Note: See the Profiler Memory Capacity table on page 31 to determine the best configuration for your requirements.

Memory size will be displayed here