HDR Features

• Handles up to three pressures (3) and two (2) temperatures (plus ambient).
• Intrinsically safe: Class I Div I Group D (without internal modem).
• Measures, records & alarms on all connected sensors every second.
• Single Alkaline “D” battery provides power for up to 4 years.
• Single Lithium “AA” Backup battery will provide 100% operation for up to 1 year after main battery is depleted.
• Wall mount, Pipe mount and Portable configuration options.
• Continuous LCD displays all inputs (selectable with scroll button): up to three pressures, two temps, ambient temp,

Main battery voltage, B/U Lithium battery voltage and active alarms. These readings are updated every second.

• 16 fully customizable alarms with logging of time and readings at the time of trip & reset on all selected alarms.
• Active alarms can be configured to blink the LCD reading every second. Scroll LCD to read the active alarm.
• Alarms can be configured to reset automatically or manually.
• Alarm Log (Records Alarm timestamps- Set & Reset).
• Delta alarms can identify and record spikes in the readings every second.
• Alarm call out to pager or phone (up to 3 phone numbers) upon any or all alarms.
• Profiler data recording (up to 20 items)/ Circular log: Selectable intervals: (1 min/ 5 min/ 10 min/ 15 min/ 30 min/ 60

min). Time/ Ave/Min/Max- Pressures 1 & 2 & 3 (If equipped)/ Ave/Min/Max- Gas Temperature 1 & 2 (if equipped)
& Ave/Min/Max ambient temp/ Main battery voltage & pulse inputs.

• Profiler selectable memory size (50,400 up to 403,200).
• “Fast logs”- (3) independent, high resolution event capture logs records and captures pressure data every second

(High, Low or Delta, selectable) for one hour total (30 minutes before the trip point and 30 minutes after).

• “Watch log”- provides an additional high resolution circular pressure data log. Recording options are: logging data

every second for 9 hours of memory storage or averaging 2 second data for 18 hours or 4 second ave. for 36 hours or
8 second ave. for 72 hours (3 days) or 16 second ave. for 144 hours (6 days) and generates an Excel file
automatically when viewed.

• Config Log (Records configuration changes made to the instrument).
• Remote Communications Ready (External Direct port & Internal Remote RS232’s).
• Multi-Drop ready- Connect remotely to several instruments from one modem (Up to 62).
• Protocols included: Sandia (Native)/ Modbus ASCII (RTU available in a future release).
• PDC (Portable Data Collector) can download & store up to 166 full profilers. No PC needed to get field data.
• Units of measure (PSIG, Ozsi G, H2O G, kPa G or Bar G, Deg. F/ Deg. C).
• Pressure ranges (shown as PSIG): 1, 3, 6, 15, 30, 60, 100, 150, 300, 500, 1000, 2000, 3000, 5000
• HDR firmware can be upgraded via PC.
• Non-volatile Flash memory saves Calibration, Transducer Coefficients, Configuration & Site info if all power is lost.
• Housing is IP64, Aluminum, Powder coated paint over chromate surface prep, lockable stainless steel hasp closure.
• HDR Host is compatible with Windows 8, Windows 7, Win Vista and Win XP.
• HDR Host is very user friendly software for configuration, calibration and data processing.
• Single PC Board design simplifies cabling and setup.
• Compact packaging for easy transport and installation.