HDR Specifications

Functionality

Profiler Data Recording:

Circular log: Large memory, recording intervals include: 1 min., 5 min., 10 min., 15 min., 30

min., 60 min. Records Min/Max/Ave Press 1,2,3, Min/Max/Ave Temp 1&2, Min/Max/Ave Ambient Temp & Batt volts

Watch Log:

P

rovides an additional high resolution circular pressure data log. Recording options are: logging data every

second for 9 hours of memory storage or averaging 2 second data for 18 hours or 4 second ave. for 36 hours or 8 second
ave. for 72 hours (3 days) or 16 second ave. for 144 hours (6 days)

Fast logs:

(3) independent, high resolution event capture logs records and captures pressure data every second

Configuration Log:

Records/timestamps configuration changes made to the instrument

Calibration Log:

Records the time and date when the sensors are calibrated.

Alarm log:

Records/timestamps and measured values of the alarms when “Set & Reset”

System Alarms:

High/Low/Delta Press 1,2,3, H/L/D Temp 1,2, Ambient Temp H/L/D, Main and back-up Battery

Pressure ranges available (shown as PSIG):

1, 3, 6, 15, 30, 60, 100, 150, 300, 500, 1000, 2000, 3000, 5000

Units of Measure

: PSIG, PSIA, InH2oG, InH2oA, InHg, mmHg, kPaG, kPaA, BarG, BarA, DegF, DegC, DegK, OzsiG,

OzsiA, Torr, Inches, Feet, Centimeter, Meters, Volts, MPH, FPS, Ft^3, M^3, Amps, Milliamps.

Non-volatile Flash Memory:

Prevents loss of calibration and configuration if all power is lost

Communication:

Two RS 232, multi-drop addressable, Sandia and modbus ASCII. (RTU available in future release).

HDR Host:

Win 7&8, Win XP & Win Vista Compatible & works with: HDR & CDR instruments

Mechanical

Housing:

Aluminum

Housing Dimensions:

7.25” x 6.25” x 4.25”

Weight:

5 lbs (including battery and on pressure transducer)

Mounting:

Wall, Pipe or Portable

Pressure Connections (X3):

¼” NPTF

Temperature Probe (X2):

¼” O.D. x 6” probe x 6’long armor; ¼” NPTM slip fitting

Coating:

IP64, Aluminum, Powder coated paint (Heath blue) over chromate surface prep

Display Scroll:

Push button switch

Security:

Stainless steel padlock hasp

Electrical

Primary Power Pack:

1.5 volt; 1 D cell alkaline battery with IS protection board.

Back Up Power:

3.6 volt field replaceable lithium cell

Transducer:

10 millivolt per volt excitation; 12 point polynomial compensation

Temperature Sensor (gas and air):

Integrated circuit type

Display:

LCD continuous eight digits- displays Press 1,2,3,Temp 1&2, ambient temp, batt volts & any active alarms

Performance

Accuracy:

+/- 0.5% of reading inclusive of linearity, hysteresis, repeatability, long term drift & temperature

Temperature:

-40°F to + 170°F

Humidity:

5 – 95 % non-condensing

Primary Power Pack Life:

Up to 48 months (1 second sample interval).

Back-Up Power Life:

Up to 12 months (1 second sample interval).

Options

External power:

Allows connecting 6V-15VDC from external power source

Inputs:

Digital pulse input with electronic recording of counts over time intervals (1 min- up to 60 min)

Outputs:

Pulse output closure upon alarm or pulse counting/ repeating

Communication:

Internal 2400 baud “land line” modem, Multi-drop harnesses, external Radio modem, Cell modem, IP

Modem, surge protection.

Certifications

Intrinsic Safe:

UL 913 and CSA C22.2, Class I, Division 1, Group D

CE:

EMC directive EN 61326-1

Corrosion Resistance:

MIL-STD-810F