Chapter 3: Board Setup and Defaults

3–3

Factory Default Switch and Jumper Settings

June 2014

Altera Corporation

Arria V SoC Development Kit

User Guide

To restore the switches to their factory default settings, perform these steps:

1. Set the DIP switch bank (SW2) to match

Table 3–1

and

Figure 3–1

.

In the following table, ON indicates the switch is to the left according to the board
orientation as shown in

Figure 3–1

.

2. Set the DIP switch bank (SW3) to match

Table 3–2

and

Figure 3–1

.

In the following table, up and down indicates the position of the switch with the
board orientation as shown in

Figure 3–1

.

Important: The default MSEL pin settings are set to all zeroes (ON) to select the fast
passive parallel x16 mode. For power-up configuration from MAX V and CFI
flash, ensure that the MAX V design uses this same mode as does in the design in
the <install dir>\kits\arriaVST_5astfd5kf40es_soc\examples\max5 directory.

Table 3–1. SW2 DIP Switch Settings

Switch

Board

Label

Function

Default

Position

1

CLK125A

Switch 1 has the following options:

ON (0) = On-board oscillator is disabled.

OFF (1) = On-board oscillator is enabled.

OFF

2

Si570

Switch 2 has the following options:

ON (0) = On-board programmable oscillator is
enabled.

OFF (1) = On-board programmable oscillator is
disabled.

ON

3

FACT LOAD

Switch 3 has the following options:

ON (0) = Load the user design from flash at
power up.

OFF (1) = Load the user factory from flash at
power up.

OFF

4

Security

Switch 4 has the following options:

ON (0) = On-Board USB Blaster II sends
FACTORY command at power up

OFF (1) = On-Board USB Blaster II does not
send FACTORY command at power up

OFF

Table 3–2. SW3 DIP Switch Settings (Part 1 of 2)

Switch

Board

Label

Function

Default

Position

1

MSEL0

Switch 1 has the following options:

ON (up) = MSEL0 is 0.

OFF (down) = MSEL0 is 1.

ON

2

MSEL1

Switch 2 has the following options:

ON (up) = MSEL1 is 0.

OFF (down) = MSEL1 is 1.

ON

Advertising