Altera PowerPlay Early Power Estimator User Manual

Page 11

Advertising
background image

Chapter 2: Setting Up Cyclone III PowerPlay Early Power Estimator

2–5

Entering Information into the PowerPlay Early Power Estimator

© June 2009 Altera Corporation

PowerPlay Early Power Estimator User Guide for Cyclone III FPGAs

1

After importing a file, you must verify all your information.

Importing a file from the Quartus II software populates all input parameters on the
Main page that is specified in the Quartus II software. These parameters include:

Family

Device

Package

Temperature grade

Power characteristics

Ambient or junction temperature

Airflow

Heat sink

Custom 

SA

or Custom 

JA

Board thermal model

The ambient or junction temperature, airflow, heat sink, Custom 

SA

or Custom 

JA

,

and board thermal model parameters are optional.

For more information about these parameters, refer to

“Main Input Parameters” on

page 3–1

.

The f

MAX

values imported into the PowerPlay Early Power Estimator are the same as

the f

MAX

values specified by the designer in the Quartus II software. You can manually

edit the f

MAX

and the toggle percentage in the PowerPlay Early Power Estimator to suit

your system requirements.

Advertising