Altera PowerPlay Early Power Estimator User Manual

Page 14

Advertising
background image

3–2

Chapter 3: Using Cyclone III PowerPlay Early Power Estimator

PowerPlay Early Power Estimator Inputs

PowerPlay Early Power Estimator User Guide for Cyclone III FPGAs

© June 2009 Altera Corporation

Table 3–1

describes the values that must be specified in the Main section of the

PowerPlay Early Power Estimator.

Table 3–1. Main Section Information (Part 1 of 2)

Input Parameter

Description

Family

Select the device family.

Only the Cyclone III device family is available.

Device

Select your device.

Larger devices consume more static power and have higher clock dynamic power. All other
power components are unaffected by the device.

Package

Select the package that is used.

Larger packages provide a larger cooling surface and more contact points to the circuit board,
leading to lower thermal resistance. Package selection does not affect dynamic power.

Temperature Grade

Select the appropriate temperature grade.

This field only affects the maximum junction temperature.

Power Characteristics

Select the typical or theoretical worst-case silicon process.

Currently, only the typical silicon process is available for Cyclone III LS devices.

There is process variation from die-to-die. This primarily impacts the static power
consumption. Typical provides results that line up with average device measurements.

Junction Temp, T

J

(°C)

Enter the junction temperature of the device. This value can range from 0°C to 85°C for
commercial grade devices and -40°C to 100°C industrial grade devices.

This field is only available when you select User Entered T

J

. In this case, junction temperature

is not calculated based on the thermal information provided.

Ambient Temp, T

A

(°C)

Enter the air temperature near the device. This field is only available when you select Auto
Computed T

J

.

If Estimated Theta JA is selected, this field is used to compute junction temperature based on
power dissipation and thermal resistances through the top-side cooling solution (heat sink or
none) and board (if applicable).

If Custom Theta JA is selected, this field is used to compute junction temperature based on
power dissipation and the custom

JA

entered.

Heat Sink

Select the heat sink being used. You can specify no heat sink, a custom solution, or specify a
heat sink with set parameters. This field is only available when you select Auto Computed T

J

and Estimated Theta JA.

Representative examples of heat sinks are provided. Larger heat sinks provide lower thermal
resistance and thus lower junction temperature. If the heat sink is known, refer to the data
sheet and enter a Custom heatsink-to-ambient value according to the airflow in your system.

The heat sink selection updates

SA

and the new value is seen in the Custom

SA

(°C/W)

parameter. If you select a custom solution, the value is the same as the value entered for
Custom

SA

(°C/W).

Airflow

Select an available ambient airflow in linear-feet per minute (lfm) or meters per second (m/s).
The options are 100 lfm (0.5 m/s), 200 lfm (1.0 m/s), 400 lfm (2.0 m/s), or still air. This field
is only available when you select Auto Computed T

J

and Estimated Theta JA.

Increased airflow results in a lower case-to-air thermal resistance and thus lower junction
temperature.