Stratix IV GX FPGA Development Kit User Guide

Performance Indicators

These controls display current transaction performance analysis information collected
since you last clicked Start:

Write

, Read, and Total performance bars—Show the percentage of maximum

theoretical data rate that the requested transactions are able to achieve.

Write (MBps)

, Read (MBps), and Total (MBps)—Show the number of bytes of

data analyzed per second. The top port data bus is 16 bits wide and the frequency
is 533 MHz double data rate (1066 Mbps per pin), equating to a theoretical
maximum bandwidth of 2132 MBps. The bottom port data bus is 64 bits wide and
the frequency is 533 MHz double data rate (1066 Mbps per pin), equating to a
theoretical maximum bandwidth of 8528 MBps.

1

Performance figures are based on a 100-MHz input clock from
programmable oscillator X6. Using the

“The Clock Control” on page 6–22

to

adjust the frequency changes the circuit speed in real time and the DDR3
tab performance indicators, which are capped at 100% for increased
frequencies. Physical layer speeds equal the oscillator X6 frequency times
the input PLL multiplier ratio. The default is 533 MHz (100 MHz × 5.33) or
1066 Mbps per pin. Changing the oscillator X6 frequency to 125 MHz
changes the circuit speed to 667 MHz or 1333 Mbps per pin. Typically you
need to reset the DDR3 design after changing the clock frequency.

Error Control

The Error control controls display data errors detected during analysis and allow you
to insert errors:

Detected errors

—Displays the number of data errors detected in the hardware.

Inserted errors

—Displays the number of errors inserted into the transaction

stream.

Insert Error

—Inserts a one-word error into the transaction stream each time you

click the button. Insert Error is only enabled during transaction performance
analysis.

Clear

—Resets the Detected errors and Inserted errors counters to zeros.

Number of Addresses to Write and Read

The Number of addresses to write and read control determines the number of
addresses to use in each iteration of reads and writes. Valid values range from 2 to
16,777,216.

Data Type

The Data type control specifies the type of data contained in the transactions. The
following data types are available for analysis:

PRBS

—Selects pseudo-random bit sequences.

Memory

—Selects a generic data pattern stored in the on chip memory of the

Stratix IV GX device.