Port, Start, Stop – Altera Stratix IV GX FPGA User Manual
Page 37: Performance indicators, Error control, Number of addresses to write and read
Chapter 6: Board Test System
6–13
Using the Board Test System
March 2014 Altera Corporation
Stratix IV GX FPGA Development Kit User Guide
Port
The Port control directs communication to one of two QDR II+ ports on your board.
Start
The Start control initiates QDR II+ memory transaction performance analysis.
Stop
The Stop control terminates transaction performance analysis.
Performance Indicators
These controls display current transaction performance analysis information collected
since you last clicked Start:
■
Write
and Read performance bars—Show the percentage of maximum theoretical
data rate that the requested transactions are able to achieve.
■
Write (MBps)
and Read (MBps)—Show the number of bytes of data analyzed per
second. The QDR II+ buses are 18 bits wide for both read and write, and the
frequency is 400 MHz double data rate (800 Mbps per pin), equating to a
theoretical maximum bandwidth of 1800 MBps, and 3600 MBps for simultaneous
read and write.
1
Performance figures are based on a 100-MHz input clock from
programmable oscillator X6. Using the
“The Clock Control” on page 6–22
adjust the frequency changes the circuit speed in real time and the QDR II+
tab performance indicators, which are capped at 100% for increased
frequencies. Physical layer speeds equal the oscillator X6 frequency times
the input PLL multiplier ratio. The default is 400 MHz (100 MHz × 4.00) or
800 Mbps per pin. Changing the oscillator X6 frequency to 125 MHz
changes the circuit speed to 500 MHz or 1000 Mbps per pin. Typically you
need to reset the QDR II+ design after changing the clock frequency.
Error Control
The following controls display data errors detected during analysis and allow you to
insert errors:
■
Detected errors
—Displays the number of data errors detected in the hardware.
■
Inserted errors
—Displays the number of errors inserted into the transaction
stream.
■
Insert Error
—Inserts a one-word error into the transaction stream each time you
click the button. Insert Error is only enabled during transaction performance
analysis.
■
Clear
—Resets the Detected errors and Inserted errors counters to zeros.
Number of Addresses to Write and Read
The Number of addresses to write and read control determines the number of
addresses to use in each iteration of reads and writes. Valid values range from 2 to
1,048,576.