26

Altera Corporation

SerialLite II Protocol Reference Manual

Physical Layer Description

Training Sequence One Ordered Set Sequence {|TS1|}

The first link training sequence consists of eight ordered sets as shown in

Table 2–13

. This sequence is used to initialize the links.

Training Sequence Two Ordered Set Sequence {|TS2|}

The second link training sequence consists of eight ordered sets as shown
in

Table 2–14

. This sequence is used to indicate that link initialization is

complete, and forms part of the link-deskew sequence.

Table 2–13. {|TS1|} Composition

Field

Ordered Set

Description

TC

||COM||

Comma (or Sync) identifier

LN

||DAT||

Lane number. A number from 0 to 255 (in
8-bit space, encoded before transmission,
with 0 representing the most significant
lane)

MLN

||DAT||

Maximum lane number. A number from 0 to
255 (in 8-bit space, encoded before
transmission, with 0 representing a single
lane implementation)

TSZ

||DAT||

Transfer size. Valid numbers are 1, 2, and
4. The transfer size defines the number of
columns for a contiguous burst of data; 1
column, 2 columns, 4 columns, and all
other values are reserved.

RSV

3x||DAT||

Reserved. Set to all zeros (D0.0); repeated
three times

T1

||DAT||

First training sequence identifier (D10.2)

Table 2–14. {|TS2|} Composition

Field

Ordered Set

Description

TC

||COM||

Comma (or Sync) identifier

LN

||DAT||

Lane number. A number from 0 to 255 (in
8-bit space, encoded before transmission,
with 0 representing the most significant
lane)

MLN

||DAT||

Maximum lane number. A number from 0 to
255 (in 8-bit space, encoded before
transmission, with 0 representing a single
lane implementation)

Advertising