Packets marked bad, Status indication – Altera SerialLite II Protocol User Manual

Page 74

Advertising
background image

74

Altera Corporation

SerialLite II Protocol Reference Manual

Error Events & Handling

Packets Marked Bad

A transmitted packet is tagged with the {EBP} sequence under the
following conditions:

User-side interface protocol error for user packets

User-indicated packet is bad through the assertion of TERR on the
user-side interface

Upon receiving packets with {EBP}, the receiver forwards the packets
to the user logic and asserts the error signal on the user-side interface

Status Indication

The SerialLite II protocol requires a status port to indicate various errors
and internal operating status.

Table 2–26

lists the required status signals.

Table 2–26. Status Output Signal Assignments

Name

Type

Logic

Description

LINK_UP

Static

Active high

0 = Indicates link initialization status
1 = Indicates link active status

CATA_ERR

Static

Active high

0 = No catastrophic errors
1 = Catastrophic error detected

LINK_ERR

Pulsed

Active high

0 = No link errors
1 = Link error detected

DATA_ERR

Pulsed

Active high

0 = No data errors
1 = Data error detected

Advertising