Atlona AT UHD CLSO 612 V2 User Manual

Page 28

Advertising
background image

28

atlona.com

Toll free: 1-877-536-3976

Local: 1-408-962-0515

Command

Feedback

Description

IPCFG

IP Addr : x.x.x.x
Netmask : x.x.x.x
Gateway : x.x.x.x
IP Port : x

Displays IP address configure

IPQuit

IPQuit

Telnet Logout

IPAddUser [X] [Y]

IPAddUser [X] [Y]

IPAddUser [name] [password]. Add user of telnet.
If only command write “IPAddUser”, it will display all user list.
=> IPAddUser

IPDelUser [Y]

IPDelUser [Y]

IPDelUser [name]. Del user of telnet

IPDHCP [Y]

IPDHCP [Y]

IPDHCP [on/off/sta]. Set DHCP mode status and auto reset telnet.
Ex: Set DHCP mode is on => IPDHCP on

IPStatic [X] [Y] [Z]

IPStatic [X] [Y] [Z]

IPStatic [Address] [Netmask] [Gateway]. Set static IP address and
auto reset telnet.
Ex: Set static IP address is 192.168.1.1 255.255.255.0
192.168.1.254
=> IPStatic 192.168.1.1 255.255.255.0 192.168.1.254

IPPort [Y]

IPPort [Y]

IPPort [port]. Set telnet port and auto reset telnet
Ex: Set telnet port 80 => IPPort 80

IPLogin [Y]

IPLogin [Y]

IPLogin [on/off/sta]. Set telnet login status.
Ex: Set telnet login is on => IPLogin on

Broadcast [Y]

Broadcast [Y]

Broadcast [on/off/sta]. Broadcast switch.
Ex: Set broadcast mode is on => Broadcast on

IPTimeout [Y]

IPTimeout [Y]

IPTimeout [Sec]. Set telnet idle timeout time. Default is 2 minute.
Ex: Set telnet idle timeout 10 minutes => IPTimeout 600

Each command is terminated with a carriage return.
Feedback is terminated with a carriage return and line feed.

Note: If the command fails or is incorrect the feedback should be “Command FAILED”

IP Commands

Baud Rate

Zone RS-232 port conifiguration must match the connected device on all parameters including baud
rate, data-length, parity, and stop-bit. These parameters can easily be set using the WebGUI or
following commands through RS-232 or TCP/IP.
The baud rate for the switcher is for switcher control and the transmitter/receiver baud
rate is for control of the RS-232 device in zone.
All commands from your control processor are
at the settings for the switcher. The switcher will modify the baud rate and other settings to these
set parameters by zone.

Note: Baud rate options 2400, 4800, 9600, 19200, 38400, 57600, or 115200

Note: Default for the switcher is: Baud rate-115200bps, Data length-8bit, Parity-None, Stop Bit-1

Command for Switcher Parameters

CSpara[baudrate,data-length,parity,stop-bit] (data, parity, and stop bit for switcher must be 8,0,1)

For example if you wish to change the baud rate of the switcher to 38400 the command would
look like this:

CSpara[38400,8,0,1]

Advertising