background image

Getting Started With

CEL-553, CEL-573 & CEL-593

Sound Level Analysers

“Series 3”

“Series 3” of the CEL-500 analysers

introduces a new instrument: the CEL-553

which is available ONLY as a real-time

third-octave sound level meter, with user

initiated storage of screen data.

Instruments in Series 3 can measure

noise levels, calculate the commonly

required time averaged parameters and

save the results.

The standard memory is capable of

storing about 200 000 data points, which is

equivalent to 6 000 data screens while the

optional extended memory can store

approximately 1 000 000 data points,

equivalent to 30 000 data screens.

Depending on model they can also

analyse and store noise data in broadband

and octave bands.

With the exception of the CEL-553

which has only SLM mode, the standard

versions of these instruments can be

operated in three different ways

(measurement modes) as follows.

¤

Real time sound level meter with user

initiated storage of screen data.

¤

Event sound level meter with manual,

remote or threshold triggering

(CEL-593 only).

¤

Environmental sound level meter with

user selected sampling periods

(CEL-573 and CEL-593).

The measurement parameters available on

standard versions vary from model to

model and from mode to mode as shown

in Table 1 on page 73.

To simplify measurement procedures,

pre-programmed setups are stored by the

instrument. There is a separate directory

for each application, mode and bandwidth,

each of which contains one initial setup

provided by the factory, and up to six more

defined by the user. Similarly, stored data

can be accessed via separate directories

for each bandwidth, or via an additional

directory that includes ALL data.

The following additional measurement

applications can be installed.

¤

Fastore capability that samples and

saves data at very short time intervals.

¤

Building Acoustics.

¤

Loudness Determination.

Each instrument in the series can be up-

(or down-) graded to any other model, to

include more (or fewer) features. Consult

your local agency or CEL for details.

Series 3 instruments with Version 7

and later firmware feature a revised

startup sequence where Application,

Acquisition Mode and Bandwidth are

selected via separate menu screens, plus

the option of measuring sound exposure

level (SEL) in broadband SLM and a

revised keypad appearance.

For a description of all CEL-500 series

instruments, also refer to the Reference

Handbook.