Editing stored set ups – Casella CEL CEL-593 User Manual

Page 14

Advertising
background image

OPTIONS

CONFIGURATION

CALIBRATE
SET CLOCK

DELETE MEMORY

MIC. RESPONSE

SELECT

GS-03

STOP

SLM

LCD CONTRAST
SET UP RS 232

SET PRINTER

POL. VOLTS
SET RUN I. D.

-

/

-

SET CLOCK

Allows time and date to be set.

MIC. RESPONSE

Allows microphone response to be

changed between free field to meet IEC

standards and random incidence that

meets ANSI standards.

CONFIGURATION

Displays the instrument configuration.

LCD CONTRAST

Allows the display contrast to be changed.

SET PRINTER

Allows the printer output format to be

specified as Epson dot matrix or Laserjet

compatible so data displayed on the

screen can be printed via a CEL-501

Parallel (Centronics) Interface (Chapter 8).

SETUP RS232

Allows the RS232 baud rate to be speci-

fied so that stored data can be transferred

over a CEL-502 RS232 Interface.

POL. VOLTS

Allows the 200 V polarising voltage

required for condenser microphones to be

switched OFF to permit electret

microphones to be used (Chapter 4).

RUN I.D.

Allows an identity code consisting of a

single letter and three numbers to be

assigned to each run by means of NEXT

VALUE and PREV. VALUE keys.

11.

Editing Stored Set Ups

Setup/Review - Screen Options

Previous

Screen

Next/
Previous
Value

Next
Screen

Previous Mode

Next Mode

980008e

Select
Screen
Entries

Backlight

"Series 3 & 2"

When switched ON, the set ups marked

will be loaded for each measurement

mode and bandwidth, for immediate use.

Up to seven set ups can be stored for

each available bandwidth and mode, giving

the following maximum numbers for an

instrument without additional applications.

CEL-553: 7 x 3 x 1 = 21,

CEL-573: 7 x 3 x 2 = 42,

CEL-593: 7 x 3 x 3 = 63.

Table 1 on page 15 lists the bandwidths,

operating modes and measurement

parameters available for all instruments in

the CEL-500 series.

Each bandwidth has its own directory,

where the first entry is an INITIAL SET UP

provided by the factory (Figure 1) which

can neither be deleted nor overwritten.

Any stored set up can be edited and

the changed version used with or without

saving. However, if an edited version of

the initial set up is to be saved, it must be

given a new identity. Set ups other than

the initial set up may be overwritten.

When a set up has been modified

for use with no intent to save it, do

not press the LOAD key as this will

reload the un-modified version.
With the instrument in Stop mode (i.e. not

logging data), starting from a Status

screen, edit and store a set up as follows.

1. Press

or

keys sufficient times to

display the required mode and

bandwidth in the Application Box.

Page 72 - Getting Started - CEL-553/573/593

Advertising
This manual is related to the following products: