Diagnostic, Level 1, Level 2 – CUE smartCUE User Manual

Page 19

Advertising
background image

User Manual Interfaces

www.cuesystem.com

Page 19 of 44

5.5. Diagnostic ..................................................................

5.5.1. Level 1

After switching on the smartCUE interface the LED DATA O.K. is blinking (with the Morse sign OK)
provided that the auto-diagnostics are in order. The internal microprocessor and basic internal circuits
are being tested. The tests for output line drivers are not included at this level.

5.5.2. Level 2

In the Test Mode the smartCUE is ready for standard operation but it sends out system messages via
DATA IN connector. These system messages help to identify possible problem.

Pressing the TEST and RESET buttons, then release RESET, wait few seconds. Interface smartCUE
transmits via DATA IN serial channel (19200,8,e,2)

• Version of the firmware
• Information about IR interface
• Checksum of the firmware
• System messages are transmitted during IR code transmitting (firmware version dependent)