7.3.4. Addressing

BANK selector
It serves for bank setting. Default value is 0. Onto one CUEring there can be connected more than one
analogCUE interface. Each of them must have different BANK setting.
There can be up to (320) analog output ports in one system hence a maximum of (10) analogCUE
interfaces on one CUEring. The BANK from 0 to 9 can be set up using the front panel switch. The
different value of bank must be set to each analogCUE in one system.

Addressing with Assistant or Assistant-S
The analog output ports located inside the Assistant or Assistant-S are addressed in the same way as
the analog output ports located in the analogCUE. The default bank for analog output ports located
inside the Assistant or Assistant-S is 0. Should this annoy you, then switch over the BANK switch at
the analogCUE to value from 1 to 9. Or there also exist possibility select by software another bank for
analog output ports in Assistant or Assistant-S.

7.4. Diagnostic ..................................................................

7.4.1. Level 1

After switching on the analogCUE the LED DATA O.K. (with the Morse sign OK) is blinking provided
that the auto-diagnostics are in order. The internal microprocessor and the output circuits are being
tested.

7.4.2. Level 2

As long as you keep the button TEST pressed all outputs are set on 100%.

7.4.3. Level 3

When you connect the testing adapter (connector DB-9-male which makes shortage between pins 2
and 3) to the DATA IN connector you have to keep the button TEST pressed after power on. This way
you can set the analogCUE to the testing mode. The interface analogCUE is then transmitting itself
the message, receives the message in the testing device, evaluates and executes it. The diodes are
signaling in the same way as with the diagnostics Level 2.