REGULAR CARE

12

TEMPERATURE PRESSURE RELIEF VALVE

This valve is near the top of the water
heater and is essential for its safe
operation. It is possible for the valve to
release a little water through the drain
line during each heating period. This
occurs as the water is heated and
expands by approximately 1/50 of its
volume.

Continuous leakage of water from the
valve and its drain line may indicate a
problem with the water heater (refer to

“Temperature Pressure Relief Valve
Running”

on page 18).

Warning: Never block the outlet of

this valve or its drain line for any reason.

Operate the easing lever on the
temperature pressure relief valve once
every six months. Refer to

“Minor Six

Month Maintenance”

on page 11. It is

very important the lever is raised and
lowered gently.

Warning: Failure to do this may

result in the water heater cylinder
failing.

Warning: Exercise care to avoid

any splashing of water, as water
discharged from the drain line will be
hot. Stand clear of the drain line’s point
of discharge when operating the valve’s
lever.

If water does not flow freely from the drain line when the lever is lifted, then the
water heater must be checked. Phone Aquamax Service to arrange for an
inspection.

The temperature pressure relief valve should be replaced at intervals not
exceeding 5 years, or more frequently in areas where there is a high incidence
of water deposits (refer to

“Water Supplies”

on page 13).






water

heater

drain

line

lift until water

flows from the

drain line

lower gently