Mains pressure, Precautions, To turn off the water heater – AquaMAX G135VE User Manual

Page 7: To turn on the water heater, Going on holidays

Advertising
background image

ABOUT YOUR WATER HEATER

7

MAINS PRESSURE

The water heater is designed to operate at mains pressure by connecting directly
to the mains water supply. If the mains supply pressure in your area exceeds
that

shown on page

22, a pressure limiting valve must be fitted. The supply

pressure should be greater than 350 kPa for true mains pressure operation to be
achieved.

PRECAUTIONS

Where damage to property can occur in the event of the water heater leaking,
the water heater must be installed in a safe tray. Construction, installation and
draining of a safe tray must comply with AS/NZS 3500.4 and all local codes and
regulatory authority requirements.

The water heater must be maintained in accordance with the Owner’s Guide and
Installation Instructions. Refer to

“Regular Care”

on page 9 and to

“Anode

Inspection and Replacement”

on page 14.


If this water heater is to be used where an uninterrupted hot water supply is
necessary for your application or business you should ensure that you have back
up redundancy within the hot water system design. This should ensure the
continuity of hot water supply in the event that this water heater were to become
inoperable for any reason. We recommend you seek advice from your plumber
or specifier about your needs and building back up redundancy into your hot
water supply system.

TO TURN OFF THE WATER HEATER

If it is necessary to turn off the water heater:

Shut down the gas control (refer to

“Close Down Procedure”

on page 36).

Close the gas isolation valve at the inlet to the gas control.

Close the cold water isolation valve at the inlet to the water heater.

TO TURN ON THE WATER HEATER

Open the cold water isolation valve fully at the inlet to the water heater.

Open the gas isolation valve fully at the inlet to the gas control.

Light the water heater (refer to

“Lighting the Water Heater”

on page 34).

GOING ON HOLIDAYS

If you are going on holiday for more than a few days the thermostat can be set
to the “” (pilot) position to conserve energy (refer to point 1 of

“Close Down

Procedure”

on page 36). If it is necessary to turn off the water heater, refer to

“To

Turn Off The Water Heater”

on page 7.

Advertising