Lighting instructions – AquaMAX G135VE User Manual

Page 35

Advertising
background image

LIGHTING THE WATER HEATER

35

LIGHTING INSTRUCTIONS

Using the gas control light the water heater as follows:

1.

Stop,

read the safety information

on page 34.

2.

Remove the access cover.

3.

Turn the gas control knob fully clockwise to the “” (off) position.

4.

Wait five (5) minutes so any build up of unburnt gas can escape. If you then
smell gas, stop and follow “C” in the safety information. If you do not smell
gas, proceed to step 5.

5.

Turn the knob to t

he “” (pilot) position.

6.

Depress the knob fully (until star disappears below housing) and after
30 seconds, whilst keeping the knob depressed, repeatedly press the igniter
button (for up to 40 seconds) until the pilot flame ignites.

Warning: Keep your face clear of the combustion chamber opening

while pressing the igniter.

Note: It is not possible to depress the knob fully if the gas control has
activated its safety shut-off feature. In this case, wait 60 seconds for the gas
control to reset.

7.

Keep the knob depressed for 20 seconds after the pilot flame lights.

8.

Release the knob and check the pilot is still alight. The pilot can be checked
by looking through the large opening below the gas control.

9.

If the pilot has failed to light or has not remained alight, turn the gas control
knob to the "

” (off) position. Wait five (5) minutes for any unburnt gas to

escape and then begin again at step 5.

Warning: Failure to wait five (5) minutes may result in a fire or explosion.

10. When the pilot flame remains alight with the gas control knob released, turn

the knob anticlockwise to the setting of

‘5’. This will give a water temperature

of about 60°C.

11. Refer to

“Temperature Adjustment”

on page 5, if further temperature

adjustment is required.

12. Replace the access cover.


The main burner will now automatically ignite when heating is required and
extinguish when the water has been heated to the set temperature. If the main
burner does not light at the selected setting, the water may already be at the
selected temperature.

Note: Never press the igniter button while the top knob is in a numbered position.

Advertising