WATER SUPPLIES

16

CHANGE OF WATER SUPPLY

The changing or alternating from one water supply to another can have a
detrimental effect on the operation and / or life expectation of a water heater
cylinder and a temperature pressure relief valve.

Where there is a changeover from one water supply to another, e.g. a rainwater
tank supply, bore water supply, desalinated water supply, public reticulated water
supply or water brought in from another supply, then water chemistry information
should be sought from the supplier or it should be tested to ensure the water
supply meets the requirements given in these guidelines for the Aquamax
warranty to apply.

SUMMARY OF WATER CHEMISTRY ADVICE AFFECTING WARRANTY

The water heater and its components are not suitable for certain water
chemistries. Those chemistries are listed below. If the water heater is connected
at any time to a water supply with the following water chemistry, the Aquamax
warranty will not cover any resultant faults on the components listed below:

Water Chemistry

Component

Total Dissolved Solids (TDS) > 2500 mg/L

water heater cylinder

Total Dissolved Solids (TDS)
not suitable for anode type

water heater cylinder

Saturation Index (SI) > +0.4
(if expansion control valve is not fitted)

water heater cylinder
temperature pressure relief valve