ANODE INSPECTION AND REPLACEMENT

The anode installed in a vitreous enamel lined steel water heater cylinder will
slowly dissipate whilst protecting the cylinder. The life of the cylinder may be
extended by replacing the anode.

If the anode is not replaced during a five year service (refer to

“Major Five Year

Service”

on page 10) then the maximum time after installation when the anode

should be replaced for this gas water heater is 8 years.

For water supplies which are either softened, desalinated or where the water
supply may alternate between a water tank and a reticulated public supply or
another supply, it is recommended the anode be replaced within 5 years of
installation.

CAUTION

If the water supply has a TDS greater than 150 mg/L and a green anode has not
been changed to a black anode, or if the TDS is greater than 600 mg/L and the
anode has not been changed to a blue anode, there is the possibility the anode
may become overactive and hydrogen gas could accumulate in the top of the
water heater during long periods of no use. In areas where this is likely to occur,
the installer should instruct the householder on how to dissipate the gas safely.

If, under these conditions, the water heater has not been used for two or more
weeks the following procedure should be carried out before using any electrical
appliances (automatic washing machines and dishwashers) which are
connected to the hot water supply.

The hydrogen, which is highly flammable, should be vented safely by opening a
hot tap and allowing the water to flow. There should be no smoking or naked
flame near the tap whilst it is turned on. Any hydrogen gas will be dissipated.
This is indicated by an unusual spurting of the water from the tap. Once the water
runs freely, any hydrogen in the system will have been released.

CONDUCTIVITY - µS/cm

TOTAL DISSOLVED SOLIDS & CONDUCTIVITY

(vitreous enamel lined water heater cylinder)

40

150

400

600

TOTAL DISSOLVED SOLIDS (TDS) - mg/L

ANODE SELECTION

warranty applies to a vitreous enamel lined water heater cylinder if the

correct coloured anode is used for the TDS / conductivity level of water

2500

3570

no warranty

applies

to a vitreous

enamel lined
water heater

cylinder

Blue

Black

Green

60

215

570

860

0

0

Blue

Advertising