7 set-upper-threshold-info, Commands execution – Artesyn ViewCheck on ATCA-7370 Installation and Use (April 2014) User Manual

Page 69

Advertising
background image

Commands Execution

ViewCheck on ATCA-7370 Installation and Use (6806800S48B)

69

5.4.7

set-upper-threshold-info

set-upper-threshold-info

command is used to set the upper threshold value for a

particular monitor based on which the monitor performs.

Syntax for CLI
set-upper-threshold-info monitorId < Monitor ID> deviceInstance

<Dev Instance> upperThreshold <Threshold Value>

Syntax for XML
<Script>

<InvokeMethod>

<Object>

<Class>deviceCategory</Class>

<Name>vee0-{Dev Cat}</Name>

</Object>

<Method>setUpperThresholdInfo</Method>

<Argument>

<Name>deviceInstance</Name>

<Value>Dev Instance</Value>

</Argument>

<Argument>

<Name>monitorId</Name>

<Value>Monitor ID</Value>

</Argument>

<Argument>

<Name>upperThreshold</Name>

Dev Instance

Enum

Use list-device-instances CLI command to get the
equivalent enumerated value of supported Device
Instance

Threshold
Value

Integer

Type a threshold value for the specified monitor ID

Table 5-13 set-lower-threshold-info

Argument

Data Type

Description

Advertising