7 set-upper-threshold-info, Commands execution – Artesyn ViewCheck on ATCA-7370 Installation and Use (April 2014) User Manual
Page 69
Commands Execution
ViewCheck on ATCA-7370 Installation and Use (6806800S48B)
69
5.4.7
set-upper-threshold-info
set-upper-threshold-info
command is used to set the upper threshold value for a
particular monitor based on which the monitor performs.
Syntax for CLI
set-upper-threshold-info monitorId < Monitor ID> deviceInstance
<Dev Instance> upperThreshold <Threshold Value>
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>deviceCategory</Class>
<Name>vee0-{Dev Cat}</Name>
</Object>
<Method>setUpperThresholdInfo</Method>
<Argument>
<Name>deviceInstance</Name>
<Value>Dev Instance</Value>
</Argument>
<Argument>
<Name>monitorId</Name>
<Value>Monitor ID</Value>
</Argument>
<Argument>
<Name>upperThreshold</Name>
Dev Instance
Enum
Use list-device-instances CLI command to get the
equivalent enumerated value of supported Device
Instance
Threshold
Value
Integer
Type a threshold value for the specified monitor ID
Table 5-13 set-lower-threshold-info
Argument
Data Type
Description