6 oosd tests, 1 cpu, 2 hdd – Artesyn ViewCheck on ATCA-7370 Installation and Use (April 2014) User Manual
Page 80: 1 cpu 5.6.2 hdd
Commands Execution
ViewCheck on ATCA-7370 Installation and Use (6806800S48B)
80
As part of monitoring the Device Critical errors, all such Kernel CRITICAL and Kernel ERROR
notifications have been extracted from the PNE Kernel (4.x) driver sources and represented in
the form of a database.
The In Service Monitoring Module of ViewCheck would watch out for the occurrence of these
notifications and on detection would send a notification to XML.
The Device Errors are captured and are identified uniquely by ERROR ID. For definition of
ERROR ID, refer
.
5.6
OOSD Tests
OOSD Tests are used to monitor and manage the performance of the hardware components of
blades. You can execute these tests only when blades are offline, that is blades are not
providing any service.
5.6.1
CPU
CpuSpeedTest: Checks whether the Processor(s) frequency is in between operating limits
(upper and lower limits).
CpuTempTest: Reads the Processor core(s) temperature levels and ensures that all cores
are operating in normal levels.
CacheSizeTest: Verifies L1, L2, and L3 Cache sizes of CPU(s) on the board.
5.6.2
HDD
DiskBadBlksTest: Searches for bad blocks on a device (usually a disk partition). Device is
the special file corresponding to the device (e.g /dev/hsda1). The starting, ending block
numbers are selected in default.
DiskCntlrTest: Verifies the random data written to disks remains unchanged. It verifies only
IDE and SCSI controllers that are associated with mounted file systems. Disk controllers
associated with read-only mounted file systems are not verified.
DiskSelfTest: DiskSelfTest checks the electrical and mechanical performance as well as
read performance of the disk.