9 set-poll-interval, Table 5-15, Set-threshold-default – Artesyn ViewCheck on ATCA-7370 Installation and Use (April 2014) User Manual
Page 71: Commands execution
Commands Execution
ViewCheck on ATCA-7370 Installation and Use (6806800S48B)
71
<Argument>
<Name>monitorId</Name>
<Value>Monitor ID</Value>
</Argument>
</InvokeMethod>
</Script>]]>]]>
The following table provides the set-threshold-default command arguments.
5.4.9
set-poll-interval
set-poll-interval
command is used to set the Poll interval value for monitors.
Syntax for CLI
set-poll-interval monitorId <Monitor ID> deviceInstance <Dev
Instance> pollInterval <PollIntervaLvalue>
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>deviceCategory</Class>
<Name>vee0-{Dev Cat}</Name>
</Object>
<Method>setPollInterval</Method>
<Argument>
<Name>deviceInstance</Name>
<Value>Dev Instance</Value>
</Argument>
<Argument>
Table 5-15 set-threshold-default
Argument
Data Type
Description
Monitor ID
Integer
Type the unique ID of the Monitor for which you want to
reset its threshold value to default value
Dev Instance
Enum
Use list-device-instances CLI command to get the
equivalent enumerated value of supported Device
Instance