3 setting up hpi clients, Software installation and configuration, Table 2-4 plugin specific parameters (continued) – Artesyn System Management Interface Based on HPI-B 2.0(Centellis 4620/4440) User's Guide (June 2014) User Manual

Page 28

Advertising
background image

Software Installation and Configuration

System Management Interface Based on BBS HPI-B 2.0 (Centellis 4620/4440) User’s Guide (6806800P21D)

28

2.3

Setting Up HPI Clients

This section describes how to install/configure HPI clients on node blades.

RmcpAllowedAuthsAdmin

Allowed authentication

mechanisms for privilege

level 'operator

"none | md2 | md5
| straight"

"[none, md2, md5,
straight]"

none

RmcpGuid

RMCP group user id

16 hex bytes

[01 02 03 04 05 06 07
08 09 10 11 12 13 14 15
16] - default guid

All zeros(16

bytes)

RmcpUser[X]

X is an integer

Ex: RmcpUser2, RmcpUser3,
RmcpUser4 etc

RMCP users

<U><P><Pr><MS><A
>

U -

username

P -

Password

Pr -

Privilege

MS -

Maximum

number of sessions
A -

Authentication

[RmcpUser[2,3,4,5,6]]
are available in config file
Ex:
RmcpUser6 =
"Administrator
Administrator admin 64
none md2 md5 straight"

NA

SelMaxEntries

Maximum number of

entries in the SEL

<0…N>

[100] 1024

HPI_OEM_DISCRETE_SENSOR_D
EF_SEVERITY

HPI-B Daemon will set the

severity for the HPI events

of non-threshold sensors

based on the value

configured for this tag.
Note: If this tag is set to 3,

then change the
OPENHPI_LOG_ON_SEV
tag to
"INFORMATIONAL"

instead of "MINOR" so

that it logs events of

"INFORMATIONAL"

severity also into DEL.

<0,1,2,3>

[3]

- informational

0

- critical

1

- major

2

- minor

Commented by default,
Please uncomment in the config

file for the tag to take effect.

0

- critical

daemon will

assign the default

"critical" severity
for the events of

non-threshold

sensors(discrete/

OEM)

Table 2-4 Plugin Specific Parameters (continued)

Tag

Description

Allowed values

Default in Config. file

Built-in Default

Advertising