7 ipmi command control, Table 4-22, Hpi restart daemon state – Artesyn System Management Interface Based on HPI-B 2.0(Centellis 4620/4440) User's Guide (June 2014) User Manual

Page 61: Table 4-23, Ipmi command rdr, Table 4-24, Ipmi command control, Using hpi-b

Advertising
background image

Using HPI-B

System Management Interface Based on BBS HPI-B 2.0 (Centellis 4620/4440) User’s Guide (6806800P21D)

61

4.6.7

IPMI Command Control

IPMI command control is used to execute IPMI commands on a given resource id. This control
is created for all the FRUs in the shelf. hpiipmi client application makes use of this control to
get the IPMI commands executed.

Table 4-22 HPI Restart Daemon State

SaHpiCtrlStateT

Value

Type

SAHPI_CTRL_TYPE_DIGITAL

StateUnion.Digital

SAHPI_CTRL_STATE_PULSE_ON |

SAHPI_CTRL_STATE_OFF

Table 4-23 IPMI Command RDR

SaHpiRdrT

Value

RecordId

Assigned by HPI implementation

RdrType

SAHPI_CTRL_RDR

Entity

Entity path of the FRU
Ex: {ADVANCEDTCA_CHASSIS,6}{FAN_TRAY_SLOT,1}

{COOLING_UNIT,1}

RdrTypeUnion

Defined in next table

IdString

MOTHPI_CTRL_NAME_BOOT_OPTION

Table 4-24 IPMI Command Control

SaHpiCtrlRecT

Value

Num

MOTHPI_CTRL_NUM_IPMI_COMMAND

Type

SAHPI_CTRL_TYPE_OEM

OutputType

SAHPI_CTRL_OEM

TypeUnion.Oem.MId

OHHPI_MANUFACTURER_ID_MOTOROLA

TypeUnion.Oem.ConfigData

TypeUnion.Oem.Default.MId

OHHPI_MANUFACTURER_ID_MOTOROLA

Advertising