3 hpi domain events, Table 4-9, Domain connection sensor reading – Artesyn System Management Interface Based on HPI-B 2.0(Centellis 4620/4440) User's Guide (June 2014) User Manual

Page 48: Table 4-10, Domain connection sensor events, Hpi domain events, Using hpi-b

Advertising
background image

Using HPI-B

System Management Interface Based on BBS HPI-B 2.0 (Centellis 4620/4440) User’s Guide (6806800P21D)

48

4.4.3.3

HPI Domain Events

Depending on the connection status, the Domain Connection sensor can throw events. The
following table provides details.

Category

SAHPI_EC_AVAILABILITY

EventCtrl

SAHPI_SEC_PER_EVENT

Events

SAHPI_ES_ON_LINE | SAHPI_ES_OFF_LINE

Ignore

SAHPI_FALSE

DataFormat - ReadingFormats

SAHPI_SRF_EVENT_STATE

DataFormat - IsNumeric

SAHPI_FALSE

DataFormat - IsThreshold

SAHPI_FALSE

Oem

0

Table 4-9 Domain Connection Sensor Reading

SaHpiSensorReadingT

Value

ValuesPresent

SAHPI_SRF_EVENT_STATE

EventStatus - SensorStatus

SAHPI_SENSTAT_EVENTS_ENABLED |

SAHPI_SENSTAT_SCAN_ENABLED

AssertEvents

SAHPI_ES_ON_LINE

for a connection to a shelf

SAHPI_ES_OFF_LINE

when there is no

connection to a shelf

Table 4-8 Domain Connection Sensor (continued)

SaHpiSensorRecT

Value

Table 4-10 Domain Connection Sensor Events

Event

Description

SAHPI_ES_OFF_LINE

No connection

SAHPI_ES_ON_LINE

Connection is established. Only now is the
domain of the shelf accessible.