6 hpi restart daemon control, Table 4-20, Failed slot restore control states – Artesyn System Management Interface Based on HPI-B 2.0(Centellis 4620/4440) User's Guide (June 2014) User Manual

Page 60: Table 4-21, Hpi restart daemon rdr, Using hpi-b

Advertising
background image

Using HPI-B

System Management Interface Based on BBS HPI-B 2.0 (Centellis 4620/4440) User’s Guide (6806800P21D)

60

4.6.6

HPI Restart Daemon Control

HPI Restart Daemon control enables the user to restart the hpi-b daemon.
hpirestartdaemon

client application makes use of this control to restart the daemon.

Table 4-20 Failed Slot Restore Control states

SaHpiCtrlStateT Value

Notes

Type SAHPI_CTRL_TYPE_DIGITAL

StateUnion.Digital

SAHPI_CTRL_STATE_PULSE_ON |

SAHPI_CTRL_STATE_OFF

Table 4-21 HPI Restart Daemon RDR

SaHpiRdrT

Value

RecordId

Assigned by HPI implementation

RdrType

SAHPI_CTRL_RDR

Entity

Entity path of 'Daemon Resource'
Ex:

{ADVANCEDTCA_CHASSIS,6}

{SYS_MGMNT_SOFTWARE,0}

RdrTypeUnion.CtrlRec.Num

MOTHPI_CTRL_NUM_HPI_RESTART

_DAEMON

RdrTypeUnion.CtrlRec.Type

SAHPI_CTRL_TYPE_DIGITAL

RdrTypeUnion.CtrlRec.OutputType

SAHPI_CTRL_GENERIC

RdrTypeUnion.CtrlRec.TypeUnion.Digital.Def

ault

SAHPI_CTRL_STATE_OFF

RdrTypeUnion.CtrlRec.DefaultMode.Mode

SAHPI_CTRL_MODE_MANUAL

RdrTypeUnion.CtrlRec.DefaultMode.ReadOnly

SAHPI_TRUE

RdrTypeUnion.CtrlRec.WriteOnly

SAHPI_FALSE

RdrTypeUnion.CtrlRec.Oem

Assigned by HPI implementation.

RdrTypeUnion.CtrlRec.IdString

MOTHPI_CTRL_NAME_HPI_RESTAR

T_DAEMON

Advertising