12 installation, Fireplace placement requirements – Avalon Firestyles 564 Diamond-Fyre GSR2 Installation User Manual

Page 12

Advertising
background image

12 Installation

(for qualified installers only)

© Travis Industries

4140926

100-01395

Fireplace Placement Requirements

 The fireplace requires a 1/2" (13mm) clearance from the angled sides and back of the fireplace to the

framing members. No material (insulation, framing, etc.) may be placed into this area.

 Fireplace must be installed on a level surface capable of supporting the fireplace and vent
 Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)
 This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance

produces when determining a location.

Clearances

 When installed, walls in front of the fireplace must be a minimum 1" (25mm) to the side of the

fireplace.

 Due to the high temperature, the heater should be located out of traffic and away from furniture and

draperies.

 Fireplace must be placed so the vents below and above the glass do not become blocked.

Raised Fireplaces

 The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace

(155 Lbs.70 Kg) and vent.

 The base of the fireplace must be a minimum 70” (1778mm) below the room ceiling.

Advertising