Minimum Framing Dimensions - Rear Vent Configuration

24-1/4"

616mm

36-1/2"

927mm

33-1/2"

851mm

17-1/4"

439mm

Route the

electrical line to

a position to the

left rear of the

fireplace.

Vent Clearances for 8" (203mm) dia. Vent:

1" (25mm) to the sides, 1" (25mm) below,

and 4" (102mm) above the vent to

combustibles.

Included Firestop (required)

Part # 250-00747

Center of Rear Vent

HINT: place the fireplace so the center

line is at least 5" (127mm) from both

vertical framing members at the rear (this

allows the vent to pass through the

framing without modfications)

Minimum 38" (965mm)

Fireplace Enclosure Height

19-1/4"

489mm

32-1/2"

826mm