Finalizing the installation – Avalon Firestyles 564 Diamond-Fyre GSR2 Installation User Manual

Page 59

Advertising
background image

Finalizing the Installation

(for qualified installers only)

59

© Travis Industries

4140926

100-01395

6

Install the LP pilot orifice following the directions below.

(a) Use a 7/16” open-end wrench to remove the pilot hood.

(b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly then replace

the pilot hood, tightening the pilot hood until it is snug (do not over-tighten).

7

Replace the firebox components. Install the crushed glass. Replace the glass frame.

8

Remove the control panel to access the gas control panel. The stepper motor (adjustable regulator)
has an installation sheet included with it – make sure to follow all of the directions. Place the stepper
motor on the gas control valve (see pictures below) – MAKE SURE IT IS CORRECTLY ORIENTED.
Secure using the screws included with the motor – tighten to 25 Lb-inches. Leak test this area after
installation to verify proper installation.

9

Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve.

Advertising